Brain Atlas / 2026-10-14 / Methods

From 6,200 molecules to half a millivolt

40 seconds · 1920 × 1080 · 30 frames per second · silent

The run

MCell's rat neuromuscular junction model (MCell test suite, MIT licence), at its own setting. One quantal release of 6,200 acetylcholines, spread over 0.5–192 µs (90 % by 91 µs), was run by Brain Atlas's WebGPU kernel on native Metal and recorded every 1 µs for 5 ms (seed 7001). The model's only open receptor state is the doubly bound open state (AChR4). Its count of open receptors drives both traces. The upper panel is a render of the same run; its camera, lighting and docked poses are artist-made.

From open receptors to current and voltage

Current, under voltage clamp: I(t) = γ · Nopen(t) · (Vhold − Erev).

Voltage, in a passive single-compartment endplate: C dV/dt = −(V − Vrest)/Rin − γ · Nopen(t) · (V − Erev), with C = τm/Rin. There is no action potential and no fibre cable. The voltage is integrated with fourth-order Runge–Kutta at 1 µs, with linearly interpolated receptor counts. Halving the step changes peak depolarization by at most 1.1 × 10⁻¹² relative across all 2,000 MCell runs. A separate exponential-step calculation using each interval's mean conductance reproduces the featured run's peak to the reported precision.

Both traces are simulated.

Constants

QuantityValueSpecies, muscleMethodTemperatureSource
Single-channel conductance, γ59 pSAdult rat, flexor digitorum brevis endplate (day 21 or older)Cell-attached patch, Na Ringer with Ca20–22 °C[1]
Reversal potential, Erev0 mV (measured −7 to 0)Rat diaphragm, cut fibresVoltage clamp~23 °C[2]
Input resistance at the endplate, Rin0.39 MΩRat extensor digitorum longus (EDL)Two intracellular electrodes21 ± 2 °C[3]
Membrane time constant, τm1.3 msRat EDLIntracellular cable analysis23 °C[4]
Resting and holding potential−75 mVRat EDL and soleusThe holding potential of the comparison recordings21 °C[5]
Capacitance, C3.33 nFDerived: τm/Rin

One open receptor at −75 mV carries 4.43 pA. γ is the direct single-channel measurement in adult rat endplates. Fluctuation (noise) analysis in rat diaphragm gives about 25 pS [6]; with it, the current below would be about 0.95 nA, smaller still. A rat adult-type receptor expressed in oocytes gives 63 pS at 18 °C [7].

What the run gives

Measured rat endplates

QuantityMeasuredMuscle, methodTemperatureSource
Miniature endplate current (mEPC), peak5.31 nA (EDL), 4.91 nA (soleus)Two-electrode voltage clamp at −75 mV, µ-conotoxin21 °C[5]
3.7 nA (median)Diaphragm, voltage clamp at −80 mV22 °C[8]
3.30 nA (events under 3 nA excluded)Diaphragm, voltage clamp at −80 mV~20 °C[6]
mEPC decay time constant1.64 ms (EDL), 1.45 ms (soleus)As above21 °C[5]
1.73 msDiaphragm22 °C[8]
1.84 msDiaphragm~20 °C[6]
Miniature endplate potential (mEPP)0.60 mV (EDL), 0.65 mV (soleus)Intracellular, at −75 mV21 °C[5]
0.47 mVDiaphragm, normalised to −75 mV26–28 °C[9]

For the featured run, measured rat peak currents are 1.5–2.4 times as large as its 2.25 nA peak. The cited measurements at 20–22 °C span 3.3–5.3 nA; the MCell ensemble's 10th–90th percentile of per-run peaks is 2.11–2.30 nA.

The decay falls inside the measured range. Measured decay time constants at 20–22 °C are 1.45–1.84 ms; this model's are 1.69–1.83 ms.

The passive model omits current flow along the muscle fibre. Its 0.53 mV peak is not evidence that it reproduces a measured endplate response. Here the ratio of peak depolarization to peak clamp current is about 0.24 mV/nA; ratios formed from Wood & Slater's measured peaks are about 0.11 for EDL and 0.13 for soleus [5]. These ratios use peaks at different times and are not input resistances.

Not compared: the current's rise, 0.38–0.40 ms from 10 to 90 %. No measured rat rise times were sourced for this film.

The model's basis

The MCell test suite's model follows the rat diaphragm junction model of Stiles & Bartol [10], but is smaller. It has 46,405 receptors (10,000 on the fold crests and 2,970 per µm² mid-fold) and 1,000 acetylcholinesterases, against about 91,000 receptors and 59,000 acetylcholinesterases there. Its release and kinetics descend from lizard recordings at 22 °C [11]. The source and temperature of its receptor rate constants are not verified. Its mean open time, 0.8 ms, is in line with adult rat endplate channels near 22 °C [12].

Sources

  1. Villarroel A, Sakmann B (1996). Calcium permeability increase of endplate channels in rat muscle during postnatal development. J Physiol 496:331–338. doi:10.1113/jphysiol.1996.sp021688
  2. Glavinović MI (1979). Voltage clamping of unparalysed cut rat diaphragm for study of transmitter release. J Physiol 290:467–480. doi:10.1113/jphysiol.1979.sp012784
  3. Wood SJ, Slater CR (1995). Action potential generation in rat slow- and fast-twitch muscles. J Physiol 486:401–410. doi:10.1113/jphysiol.1995.sp020821
  4. McArdle JJ, Albuquerque EX (1973). A study of the reinnervation of fast and slow mammalian muscles. J Gen Physiol 61:1–23. doi:10.1085/jgp.61.1.1
  5. Wood SJ, Slater CR (1997). The contribution of postsynaptic folds to the safety factor for neuromuscular transmission in rat fast- and slow-twitch muscles. J Physiol 500:165–176. doi:10.1113/jphysiol.1997.sp022007
  6. Colquhoun D, Large WA, Rang HP (1977). An analysis of the action of a false transmitter at the neuromuscular junction. J Physiol 266:361–395. doi:10.1113/jphysiol.1977.sp011772
  7. Herlitze S et al. (1996). Structural determinants of channel conductance in fetal and adult rat muscle acetylcholine receptors. J Physiol 492:775–787. doi:10.1113/jphysiol.1996.sp021345
  8. Head SD (1983). Temperature and end-plate currents in rat diaphragm. J Physiol 334:441–459. doi:10.1113/jphysiol.1983.sp014505
  9. Plomp JJ et al. (1992). Adaptation of quantal content to decreased postsynaptic sensitivity at single endplates in α-bungarotoxin-treated rats. J Physiol 458:487–499. doi:10.1113/jphysiol.1992.sp019429
  10. Stiles JR, Bartol TM (2001). Monte Carlo methods for simulating realistic synaptic microphysiology using MCell. In De Schutter E (ed), Computational Neuroscience: Realistic Modeling for Experimentalists, CRC Press, 87–127.
  11. Stiles JR et al. (1996). Miniature endplate current rise times <100 µs from improved dual recordings can be modeled with passive acetylcholine diffusion from a synaptic vesicle. PNAS 93:5747–5752. doi:10.1073/pnas.93.12.5747
  12. Brenner HR, Sakmann B (1983). Neurotrophic control of channel properties at neuromuscular synapses of rat muscle. J Physiol 337:159–171. doi:10.1113/jphysiol.1983.sp014617 (abstract)

The model: MCell test suite, MIT licence.

Source file identitySHA-256 12b25d5f551e8f84610bd38d9b65d0c24888a8e35c35ffe8e3967b3945ac8939 · 28,632,641 bytes